Skip to content
Simfy Acousta Book a Site Audit

Case Studies

Four projects, set out the same way every time: what the problem was, what it measured before, what we did, and what it measured afterwards.

Home theatre01

Dedicated home theatre in a private villa

4 BHK villa · Jubilee Hills, Hyderabad
Problem
The owner wanted a real cinema room in a house where people sleep on the floor above. Bass was the risk, not volume.
Baseline
340 sq ft room, ordinary blockwork, hard floor, no isolation from the structure.
What we did
Floating floor on spring mounts, decoupled walls and ceiling, a full 7.1.4 Atmos layout, room treatment and bass trapping, fabric-finished panels.
RT60 0.38sAchieved
STC 62Wall rating
NC-22Background
AHU room02

AHU plant room in a Grade A office tower

HITEC City, Hyderabad
Problem
Three air handling units were making the floor below unusable for meetings.
Baseline
82 dB(A) measured in the plant room, 800 sq ft, three 45-tonne units.
What we did
Spring isolators under the units, a full six-surface acoustic enclosure in board and stone wool, acoustic access doors, sealed penetrations and duct treatment.
−36 dBReduction
44 dB(A)Final level
NBCCompliant
DG room03

Basement DG room, residential complex

Gachibowli, Hyderabad
Problem
Two generators in a basement under apartments. Residents were complaining every time the power went.
Baseline
104 dB(A) untreated in the DG room, two 500 kVA sets.
What we did
Spring mounts and anti-vibration pads, mass loaded vinyl inner barrier, composite wall system, exhaust and intake silencers, acoustic louvres and sealed access doors.
−42 dBReduction
32 dB(A)In apartments
CPCBCertified
Hotel04

64-room hotel, party wall upgrade

Banjara Hills, Hyderabad
Problem
Guests could hear the next room. On a renovation, the walls could not be rebuilt from scratch and rooms had to keep earning.
Baseline
Existing party walls tested at STC 36.
What we did
Double-leaf board system with stone wool infill across every inter-room partition, detailed at head, base and services penetrations — the places the number is normally lost.
STC 54Achieved
+18 ptsImprovement
64Rooms

Figures shown are from measurements taken on those projects after installation. Client names are withheld unless the client has asked to be named.

How we work

Measure. Design. Build. Verify.

Most noise complaints are not a materials problem. They are a “nobody measured it” problem.

01
Measure

We visit the site and record what is actually happening — dB levels, the frequencies carrying the noise, and where it is getting through. You cannot design against a guess.

02
Design

Targets first: the STC, IIC, NC or RT60 the room has to reach. Then the build-up that gets there, drawn and specified, with the cost itemised line by line.

03
Build

Installed by people who know why the sealant matters as much as the board. One missed penetration can cost you ten decibels of a thirty-decibel design.

04
Verify

We measure again after handover and give you the report. If it did not hit the target, that is our problem to fix, not yours to discover later.

Free · No commitment · Pan-India

Your project, next.

Tell us what you can hear. We will measure it, tell you what it will take, and put the target in writing.

  1. We call you back within one working day to understand the problem.
  2. We visit and measure — baseline dB levels and frequency profile, at no charge.
  3. You get a written proposal with performance targets, materials and costs, itemised.
Phone+91 99088 07007 Phone+91 97018 04311 Emailhello@simfyacousta.in
StudioHy End Homes, Madhapur, Hitech City
Hyderabad, Telangana – 500033
HoursMon–Sat, 9:00 AM – 6:00 PM
CoversHyderabad and pan-India projects
Call WhatsApp Book Site Audit